Optimization of the Simultaneous Determination of Sitagliptin and Metformin, in Human Plasma by A Rapid HPLC Method

Balamurugan K, Kirtimaya Mishra, Suresh R

Abstract

Simple, rapid and reproducible methods were established for quantitative determination of Sitagliptin (SIT) and Metformin (MET) spiked with plasma using an Onyx C18 Monolithic column  connected with an Onyx C18 guard cartridge.  and PDA detection at 210 nm. The mobile phase was MeOH, ACN, 0.01mM KH2PO4 (pH 3.5±0.5), adjusted with freshly prepared 10% orthophosphoric acid.  was pumped at 0.492 mL/min. The method was linear between 0.5-2.5 µg/mL, statistically validated for its linearity, precision and accuracy. The precision was found to be less than 1% showing high precision of the assay method. It was found that the excipients in the commercial tablet did not interfere with the method. Developed method can routinely use for the estimation of SIT and MET related compounds from the dosage form spiked with plasma.

Full Text:

PDF

References

Herman G, Bergman A, Liu F, Stevens C, Wang A, Zeng W, Chen L, Snyder K, Hilliard D, Tanen M, Tanaka W, Meehan A, Lasseter K.Dilzer S, Blum R, Wagner J, Pharmacokinetics and pharmacodynamic effects of the oral DPP-4 inhibitor sitagliptin in middle-aged obese subjects J Clin Pharmacol. 46 (2006) 876–886.

Ramalingam P, Udaya Bhaskar V, Padmanabha Reddy Y, Vinod Kumar K, Stability-indicating RP-HPLC Method for the Simultaneous determination of Sitagliptin and Simvastatin in Tablets, Indian J Pharm Sci. 76 (2014) 407-414.

Ravisankar P, Hassain SK, Neeha S M, Novel RP-HPLC Method for Simultanious Determination of Sitagliptin and Simvastation in Bulk and Tablet Dosage Form. IOSR Journal of Pharmacy. 5 (2015) 34-40.

Sujani PV, Padamanabha Reddy Y, Devanna N. Phanindra SS, Validated RP-HPLC Method for the Estimation of Simvastatin and Sitagliptin, Sch. Acad. J. Pharm. 3 (2014) 265-270.

Rubina Reichal C, Gopal Rao M, Development and Validation of RP-HPLC Method for Simultaneous Estimation of Gliclazide and Sitagliptin Phosphate Monohydrate in Bulk and Tablet Dosage Form, International Journal of Pharma and Bio Sciences. 6 (2015) 361-369.

Lavanya R, Yunoos Md, Development and Validation of RP-HPLC method for the estimation of Sitagliptin Phosphate in Bulk and its Tablet Dosage Form, Journal of Advanced Pharmacy Education & Research. 3 (2013) 475-479.

Habibulla ,. Sreenivas Rao T, Sreedhar C, Ashok R, Swetha K, Analytical method development and validation for some oral hypoglycemic drug, DHR-International Journal of Pharmaceutical Sciences. 5 (2014) 80-87.

Arun M Kashid, Anup A Dhange, Vandana T Gawande, Pankaj B M, Prasanna A, Datar.Shasikant, C Dhawale, RP-HPLC method development and validation for Sitagliptin in Human Plasma, American Journal of PharmTech Research. 2 (2012) 806-811.

Jeyabalan G, Narendra N, Analytical Method Development and Validation of Sitagliptine Phosphate Monohydrate in Pure and Tablet Dosage Form by UV-Vis Spectroscopy, Research and Reviews: Journal of Pharmaceutical Analysis 1 (2012) 19-23.

Karimulla SK, Vasanth PM, Ramesh T, Ramesh M, Method development and validation of Sitagliptin and Metformin using reverse phase HPLC method in bulk and tablet dosage form. Der Pharmacia Lettre. 5 (2013) 168-174.

Ramanjaneyulu J, Nagarjuna Reddy G, Dhanalakshmi D, Ramesh B, A New Analytical Method Development and Validation for Simultaneous Estimation of Sitagliptin and Metformin Hydrochloride in Tablet Dosage form by RP-HPLC, International Journal of Pharma Sciences. 3 (2013) 360-364.

Ramalingam P, Chandra Sekhar G, Padmanabha Reddy Y, Krishna Karthik P, Stability-indicating RP-HPLC Method for Simultaneous Determination of Metformin Hydrochloride and Sitagliptin Phosphate in Dosage Forms, Chromatographia. 76 (2013) 1153-1162.

Jeyabalan G, Narendra N, Analytical method development and validation of Sitagliptine phosphate monohydrate in pure and tablet dosage form by derivative spectroscopy Journal of Applied Pharmaceutical Science 3 (2013) 095-098.

Vinit C, Atul K, UV Spectroscopic Method Development and Validation for Estimation of Sitagliptin Phosphate in Bulk and Tablet dosage form by Absorption ratio and Area under the Curve Method. jbso 1 (2013) 317-322.

Lathareddy Y, Srinivasa Rao N, Stability-Indicating RP HPLC Method and Its Validation for Analysis of Metformin & Sitagliptin in Bulk and Pharmaceutical Dosage Form, World Journal of Pharmacy and Pharmaceutical Sciences. 2 (2013) 3691-3709.

Kavitha D, Sahoo SK, Venkateswara Rao P, Nagamani M, Bhagyalaxmi CH, Development and Validation of RP HPLC Method for Determination of Metformin and Sitagliptin in Bulk and Pharmaceutical Dosage Form, Journal of Applied Pharmaceutical Research 5 (2017) 34–39.

Sankar ASK, Suraj Sythana, Aakula Jhansi, Development and Validation for Simultaneous Estimation of Sitagliptin and Metformin in Pharmaceutical Dosage Form using RP-HPLC Method, International Journal of Pharm Tech Research. 5 (2013) 1736-1744.

Vani R, Vijaya Kumer B, Krishna Mohan G, Analytical method development and validation for the determination of Sitagliptin and Metformin using reverse phase HPLC method in bulk and tablet dosage form, World Journal of Pharmacy and Pharmaceutical Sciences. 3 (2014) 1803-1811.

Refbacks

  • There are currently no refbacks.